17
GBGB
GBGB
GB
If the out is turned OFF when the SMART
function was performing the second part of the
SMT algorithm (LED SMT lit), the SMART
function will be stopped and, when the
instrument comes back to the normal control,
the smart function will also be activated.
2) If the instrument is turned OFF with the out
power off function enabled, at the next start up
this function will automatically be enabled
again.
5.75.7
5.75.7
5.7
DIRECT MODIFICATION OFDIRECT MODIFICATION OF
DIRECT MODIFICATION OFDIRECT MODIFICATION OF
DIRECT MODIFICATION OF
THE SET POINTTHE SET POINT
THE SET POINTTHE SET POINT
THE SET POINT
The set point value can be modified without using
the FUNC pushbutton.
When direct access to set point modification is
required, proceed as follows:
1) Press pushbutton or for more than
2 seconds; the set point value will be
displayed and it will start to change.
2) Using the and pushbuttons, set the
desired value.
3) When the desired value is reached, DO NOT
press any pushbutton, the new set point will
become operative 2 seconds after the
pushbuttons were last pressed and the
instrument will return to the “normal display”.
If during this procedure the modification is not to
be saved, press the FUNC pushbutton
immediately (within 2 seconds); the instrument
automatically returns to the normal display without
saving the new set point.
5.85.8
5.85.8
5.8
DISPLAYING THE SET POINT SETDISPLAYING THE SET POINT SET
DISPLAYING THE SET POINT SETDISPLAYING THE SET POINT SET
DISPLAYING THE SET POINT SET
(model 1601E)(model 1601E)
(model 1601E)(model 1601E)
(model 1601E)
To display the set point set, press the
pushbutton. The SP led lights up.
The set point value will appear on the display.
To return to the display of the value measured
press pushbutton again.
5.95.9
5.95.9
5.9
LAMP TESTLAMP TEST
LAMP TESTLAMP TEST
LAMP TEST
To check the display efficiency, press pushbuttons
+ FUNC. The instrument will turn ON, with a
50% duty cycle, all the LEDs of the display (this
state is called LAMP TEST).
No time out is applied to the LAMP TEST.
To return to the normal display mode, press
pushbuttons + FUNC again.
No other keyboard functions are available during
the LAMP TEST.