8003Issue DateApril 1994❒ USER’S MANUAL0037-752121/8 DINTemperature Controller8003 Cover 4/27/06, 2:26 PM1

Page 2 - Contents

Chromalox 8003 User's Manual 7P15 = Threshold of the “Soft Start” FunctionEnter the threshold value, in °F or °C, for the automaticstart of the &

Page 3 - Model Identification

8 Chromalox 8003 User's ManualP22 = Alarm 2 Relay ActionThis parameter is available only if P10 is different from 0and P16 is different from OFF.

Page 4 - 8003 Manual 4/27/06, 2:24 PM1

Chromalox 8003 User's Manual 9SMART FunctionSMART automatically determines the best PID controlparameters for your application.To enable the SMAR

Page 5 - 8003 Manual 4/27/06, 2:24 PM2

10 Chromalox 8003 User's ManualThe upper display will show the measured value while thelower display will show the programmed setpoint value(we d

Page 6 - Hardware Setup

Chromalox 8003 User's Manual 11td Derivative (rate), range 1 second to 9 minutesand 59 seconds. If 0, derivative is disabled.C Heating cycle time

Page 7 - Configuration Procedure

12 Chromalox 8003 User's ManualError MessagesOverrange or Underrange IndicationsThe instrument shows the OVERRANGE conditionswith the following i

Page 8 - 8003 Manual 4/27/06, 2:24 PM5

Chromalox 8003 User's Manual 13Error MessagesThe instrument has a self-diagnostic algorithm. When anerror is detected, the instrument shows “Err”

Page 9 - 8003 Manual 4/27/06, 2:24 PM6

14 Chromalox 8003 User's ManualWarranty And Limitation Of RemedyAnd ReliabilityChromalox warrants only that the Products and partsmanufactured by

Page 10 - 8003 Manual 4/27/06, 2:24 PM7

Chromalox 8003 User's Manual 15submit a claim as provided above shall specifically waiveall claims for damages or other relief, including but not

Page 11 - 8003 Manual 4/27/06, 2:24 PM8

Chromalox®INSTRUMENTS AND CONTROLS1382 HEIL QUAKER BOULEVARDLAVERGNE, TN 37086-3536PHONE (615) 793-3900FAX (615) 793-35638003 Back Cover 4/27/06, 2:25

Page 12 - Operator Mode

Chromalox 8003 User's Manual iContentsModel Identification ...

Page 13 - Output Power Off

ii Chromalox 8003 User's ManualModel IdentificationModel8003 1/8 DIN Temperature ControllerCode Output 1 - Heat or Cool1 SPDT Relay, 3 Amps at 25

Page 14 - 8003 Operator Parameters

Chromalox 8003 User's Manual 1Dimensions in inches (mm in parenthesis)ChromaloxSMRTPVMAIN AL1 AL2 SMRTFUNCCOOL HBSP0.5(12.8)3.5(89)1.9(48)3.8(

Page 15 - Error Messages

2 Chromalox 8003 User's ManualWarnings:• When a relay output is used to drive an inductiveload, it is suggested that you connect an externalsnubb

Page 16

Chromalox 8003 User's Manual 3Hardware SetupTo select the output type(s) and the alarm contact settings:1. Remove the instrument from its case.2.

Page 17 - And Reliability

4 Chromalox 8003 User's ManualGeneral OperationThere are two setup modes for the 8003:• Configuration Mode• Operator ModeIn general, the Configur

Page 18

Chromalox 8003 User's Manual 5P1 = Input Type and Standard RangeRange0 = TC type L 0 / +800 °C1 = TC type J 0 / +800 °C2 = TC type K 0 / +999 °C3

Page 19 - Chromalox

6 Chromalox 8003 User's ManualP9 = Alarm 1 InhibitAvailable only when P7 is different from 0.OFF = inhibit disabledON = inhibit enabledNote: The